3,882 research outputs found

    Radionuclide measurements by accelerator mass spectrometry at Arizona

    Get PDF
    Over the past years, Tandem Accelerator Mass Spectrometry (TAMS) has become established as an important method for radionuclide analysis. In the Arizona system the accelerator is operated at a thermal voltage of 1.8MV for C-14 analysis, and 1.6 to 2MV for Be-10. Samples are inserted into a cesium sputter ion source in solid form. Negative ions sputtered from the target are accelerated to about 25kV, and the injection magnet selects ions of a particular mass. Ions of the 3+ charge state, having an energy of about 9MeV are selected by an electrostatic deflector, surviving ions pass through two magnets, where only ions of the desired mass-energy product are selected. The final detector is a combination ionization chamber to measure energy loss (and hence, Z), and a silicon surface-barrier detector which measures residual energy. After counting the trace iosotope for a fixed time, the injected ions are switched to the major isotope used for normalization. These ions are deflected into a Faraday cup after the first high-energy magnet. Repeated measurements of the isotope ratio of both sample and standards results in a measurement of the concentration of the radionuclide. Recent improvements in sample preparation for C-14 make preparation of high-beam current graphite targets directly from CO2 feasible. Except for some measurements of standards and backgrounds for Be-10 measurements to date have been on C-14. Although most results have been in archaeology and quaternary geology, studies have been expanded to include cosmogenic C-14 in meteorites. The data obtained so far tend to confirm the antiquity of Antarctic meteorites from the Allan Hills site. Data on three samples of Yamato meteorites gave terrestrial ages of between about 3 and 22 thousand years

    Magneto-resistance in a lithography defined single constrained domain wall spin valve

    No full text
    We have measured domain wall magnetoresistance in a single lithographically constrained domain wall. An H-shaped Ni nano-bridge was fabricated by e-beam lithography with the two sides being single magnetic do- mains showing independent magnetic switching. The connection between the sides constraining the domain wall when the sides line up anti-parallel. The magneto-resistance curve clearly identifies the magnetic con- figurations that are expected from a spin valve-like structure. The value of the magneto-resistance at room temperature is around 0.1% or 0.4 ­. This value is shown to be in agreement with a theoretical formulation based on spin accumulation. Micromagnetic simulations show it is possible to reduce the size of the domain wall further by shortening the length of the bridge

    Cutaneous Sensory Mechanisms

    Get PDF
    Contains reports on two research projects.National Institutes of Health (Grant M-4235-(CZ)

    A New Approximate Min-Max Theorem with Applications in Cryptography

    Full text link
    We propose a novel proof technique that can be applied to attack a broad class of problems in computational complexity, when switching the order of universal and existential quantifiers is helpful. Our approach combines the standard min-max theorem and convex approximation techniques, offering quantitative improvements over the standard way of using min-max theorems as well as more concise and elegant proofs

    Mean lives of some states in atomic hydrogen

    Get PDF
    Measurement of mean lives of excited states in hydroge

    The O(3P) and N(4S) density measurement at 225 km by ultraviolet absorption and fluorescence in the Apollo-Soyuz test project

    Get PDF
    The densities of O(3P) and N(4S) at 225 km were determined during the Apollo Soyuz Test Project by a resonance absorption/fluorescence technique in which OI and NI line radiation produced and collimated on board the Apollo was reflected from the Soyuz back to the Apollo for spectral analysis. The two spacecraft maneuvered so that a range of observation angles of plus or minus 15 deg with respect to the normal to the orbital velocity vector was scanned. The measurements were made at night on two consecutive orbits at spacecraft separations of 150 and 500 m. The resulting relative counting rates as function of observation angle were compared to calculated values to determine the oxygen value. This value agrees with mass spectrometric measurements made under similar conditions. The nitrogen value is in good agreement with other measurements and suggests a smaller diurnal variation than is predicted by present models

    No planet for HD 166435

    Get PDF
    The G0V star HD166435 has been observed by the fiber-fed spectrograph ELODIE as one of the targets in the large extra-solar planet survey that we are conducting at the Observatory of Haute-Provence. We detected coherent, low-amplitude, radial-velocity variations with a period of 3.7987days, suggesting a possible close-in planetary companion. Subsequently, we initiated a series of high-precision photometric observations to search for possible planetary transits and an additional series of CaII H and K observations to measure the level of surface magnetic activity and to look for possible rotational modulation. Surprisingly, we found the star to be photometrically variable and magnetically active. A detailed study of the phase stability of the radial-velocity signal revealed that the radial-velocity variability remains coherent only for durations of about 30days. Analysis of the time variation of the spectroscopic line profiles using line bisectors revealed a correlation between radial velocity and line-bisector orientation. All of these observations, along with a one-quarter cycle phase shift between the photometric and the radial-velocity variationss, are well explained by the presence of dark photospheric spots on HD166435. We conclude that the radial-velocity variations are not due to gravitational interaction with an orbiting planet but, instead, originate from line-profile changes stemming from star spots on the surface of the star. The quasi-coherence of the radial-velocity signal over more than two years, which allowed a fair fit with a binary model, makes the stability of this star unusual among other active stars. It suggests a stable magnetic field orientation where spots are always generated at about the same location on the surface of the star.Comment: 9 pages, 8 figures, Accepted for publication in A&

    Coupling and induced depinning of magnetic domain walls in adjacent spin valve nanotracks

    Get PDF
    The magnetostatic interaction between magnetic domain walls (DWs) in adjacent nanotracks has been shown to produce strong inter-DW coupling and mutual pinning. In this paper, we have used electrical measurements of adjacent spin-valve nanotracks to follow the positions of interacting DWs. We show that the magnetostatic interaction between DWs causes not only mutual pinning, as observed till now, but that a travelling DW can also induce the depinning of DWs in near-by tracks. These effects may have great implications for some proposed high density magnetic devices (e.g. racetrack memory, DW logic circuits, or DW-based MRAM).Comment: The following article has been accepted by the Journal of Applied Physic
    corecore